The Asset RCR-1x Leakage Current Protection Relay has the following advantages:

  • Wide open current range, wide open time range and selectivity in leakage current
  • Test and Reset button

The Asset RCR-1x Leakage Current Protection Range series is the leakage current relays that measure and measure the current through the external current transformers. These are devices that give the command to open the circuit breaker when the leakage currents that can occur in the electric networks are observed and approach the limits that threaten the system and human health.

There are ground leaks in the networks due to reasons such as infrastructure failure, equipment failures, manufacturing faults. The RCR-1x series leakage current relay, which can limit these leaks in a wide range from 25 mA to 25 A, also has time setting between 0.02 sec and 5 sec. These features allow the use of different products according to the same product. This is 250-300mA in locations where there is no human contact but fire control is being done while the limit is 25-30mA in positions with direct human contact. The RCR-1x series can make the leakage current relay at higher limits, such as at both levels. High leakage current protection is needed in many applications such as high-power motors, electric distribution systems, mines and oil refineries.

The Asset RCR-1x Leakage Current Protection Relay is also used to apply leakage current selectivity similar to medium voltage systems. In case of a fault, the selectivity can be adjusted with the current limit on the relay and the tripping times so that the positions near the fault are opened first but the main supply is not cut off.

Thanks to the test button on the Asset RCR-1x Leakage Current Protection Relay, it is possible to check for possible leakage current relay failures. Thanks to the reset button, the system is being renewed.

According to the official gazette published on July 17, 2013, the "illegal leakage relay established in accordance with the election principle in the main panel and secondary power panels of the workplace" is obliged to use illegal current relay with the rule. With this rule, the need for leakage current relays is a must for panels without main or auxiliary distinction.
Asset RCR-1x Leakage Current Protection Relay | Technical Specifications and Table
Asset RCR-1x Leakage Current Protection Relay setting ranges are listed below:

  • Current Range: 25mA to 25A
  • Time Interval: 0.02 sec to 5 sec

Asset RCR-1x Leakage Current Protection Relay | Technicial Specifications
The Asset RCR-1x Leakage Current Protection Relay relay has the following technical characteristics:

  • Auxiliary supply range 1x110 / 230/415 Vac, 1x24 / 48 Vdc
  • External Toroidal current transformer input
  • 1x5A (250V) Relay output
  • Test and Reset Buttons
  • Wide operating range of -10 ° C ... + 60 ° C
  • 96x96 panel or rail mounting

Asset RCR-1x Leakage Current Protection Relay | Models and Options


MontajBeslemeAkım AralığıZaman AralığıRöle ÇıkışıÖzellik
RCR-1dRay Montajı (3 modül)24/48 DC 110/230/415AC25mA - 25A0,02sn. - 5sn1 x5A (250V)Test butonu Reset butonu
RCR-1p96x96mm24/48 DC 110/230/415AC25mA - 25A0,02sn. - 5sn1 x5A (250V)Test butonu Reset butonu